BMW 7 Series: Drawing Off, Evacuating And Filling Heating And Air Conditioning System (R 134a)

WARNING: Only persons in possession of a professional certificate of competence for the maintenance and repair of heating and air conditioning systems are authorized to carry out repair work on the refrigerant circuit. This certificate must be presented by 04/07/2010 at the latest. (applies only to EU countries; follow country-specific regulations in non-EU countries) Refrigerant circuit is under high pressure!

  • If the protective caps on the filling valves are difficult to open, there is a danger of injury from leaking valve inserts.

Repair work may only be carried out on a depressurized refrigerant circuit!

  • Before conducting repairs, check the actual pressure drop on the pressure gauge of the A/C service station.

Avoid contact with refrigerant and refrigerant fluid.

  • Follow safety information for handling R 134a tetrafluorethane refrigerant.
  • Follow safety information for HANDLING REFRIGERANT FLUID.

IMPORTANT: Risk of damage!

Only BMW-approved R134a refrigerant may be used.

Restart engine only when air conditioning system has been correctly filled.

Only F02/F03/F04:

To ensure a virtually complete draining of refrigerant from the automatic rear air-conditioning system or the hybrid battery cooling system: In the diagnosis system under Service functions carry out the instructions for "Draining/filling refrigerant circuit".

IMPORTANT: Risk of damage! Carefully move the climate service station! Comply with the operating instructions and maintenance intervals for the service station! The climate service station contains highly sensitive components, such as scales. These components will be damaged due to improper handling, such as fast driving over a bump. This will result in a significant reduction of the measuring accuracy when drawing off and filling.

IMPORTANT: The vehicle must be parked on the ground during all draw-off, evacuation and filling procedures! Filling a raised vehicle will result in insufficient filling levels.

NOTE: In case of complaints, carry out a heating and air conditioning performance test! If the system fails the test, draw off, evacuate and fill the heating and air conditioning system in accordance with the operating instructions of the relevant service station.

Notes for drawing off heating and air conditioning system: To help separation of refrigerant and refrigerant fluid, run engine at low speed (800-1200 RPM) and with air conditioning turned on for a few minutes.

The limits the entrainment of refrigerant fluid while it is drawn off.

Drawn-off refrigerant fluid must be changed and reintroduced via the A/C service station.

Recycling

Dispose of drawn-off refrigerant fluid as hazardous waste.

Observe country-specific waste disposal regulations.

Notes for evacuating off heating and air conditioning system: Before each filling, evacuate the refrigerant system.

Observe an evacuation time of at least 30 minutes.

The evacuation procedure removes all traces ambient air, water vapor and any other gases present from the heating and air conditioning system. This enables subsequent system filling with refrigerant.

If the vacuum does not remain stable when the system is off, run the procedure for leaks in the refrigerant circuit.

Notes for filling heating and air conditioning system: Before filling with refrigerant, replace the refrigerant fluid entrained during drawing off.

Also top up any lost fluid as indicated in the REFRIGERANT REFERENCE CHART

Loss of R134a refrigerant

REFRIGERANT REFERENCE CHART indicates the permitted loss of Refrigerant after a specific period of time. There is no leak. Refrigerant fluid may not be topped up.

REFRIGERANT FLUID TOP UP CHART indicates the amount of refrigerant fluid must be topped up with an unapproved loss of refrigerant due to a leak after a specific period time.

Different cases:

a. Loss of refrigerant per REFRIGERANT REFERENCE CHART is not exceeded

  • Top up lost R134a refrigerant
  • It is not permitted to top up to refrigerant fluid

b. Loss of refrigerant per REFRIGERANT REFERENCE CHART is exceeded

  • Top up lost R134a refrigerant
  • Refrigerant fluid must be topped up additionally per REFRIGERANT FLUID TOP UP CHART

REFRIGERANT FLUID LEVEL CHART

Air Conditioning System

REFRIGERANT FLUID LEVEL CHART

Air Conditioning System

Follow NOTES FOR OPENING AND REPLACING PARTS in refrigerant circuit.

Depending on the type of component replaced on the heating and air conditioning system, it may be necessary to top up the refrigerant fluid, even if no measurable losses have occurred during drawing off. Follow the notes provided by the heating and air conditioning system manufacturer, taking account of the tolerances (and inaccuracies) indicated in the operating instructions of the relevant service station.

Air Conditioning System
Fig. 152: Identifying Heating And Air Conditioning System Plate

Information on the required refrigerant capacity for the entire heating and air conditioning system is contained on the type plate (1) in the engine compartment.

If necessary, refer to the Technical Data for capacity.

Installation note

Reseal refrigerant filler necks on vehicle with sealing caps.

    READ NEXT:

     Instructions For Handling R 134a Refrigerant

    Work on the refrigerant circuit may only be carried out by experts! Avoid all contact with liquid or gaseous R 134a. Wear safety goggles and gloves when working on the refrigerant circuit. Follow S

     Leak Detection With Forming Gas

    NOTE: Leak detection with forming gas replaces the leak detection that is prohibited in EU countries using UV. Observe national regulations in all other countries! IMPORTANT: Compliance with the man

     Leak Detection With Ultraviolet Additives (UV Additives) (BMW Leak-Testing Case)

    IMPORTANT: The UV leakage detection procedure is not permitted in EU countries! Observe national regulations in all other countries! IMPORTANT: It is absolutely essential to read and comply with the

    SEE MORE:

     Controller

    MANUAL EMERGENCY RELEASE OF TRANSMISSION LOCK Manual emergency release of transmission lock from inside vehicle is not possible with GA6HP/GA8HP gearboxes from 03/2010 From production date 04/2010 on, the transmission lock release cable is not fitted on: F01/F02/F03 GA6HP from production date

     Introduction

    Integrated Chassis Management (ICM) History A central, higher-level driving dynamics control system was first introduced in BMW vehicles several years ago. The introduction of the longitudinal dynamics management system in the BMW 3 Series (E9x) was the first step in this direction. The longitudi