NOTES ON INITIALIZING ELECTRIC SEAT ACTUATOR DRIVES
NOTE: Initialization is carried out at the adjusting switch of the relevant seat.
In this process, the end positions of the relevant electric seat actuator drive are recorded and stored.
An initialization must be performed:
Operating sequence for initialization:
Move corresponding seat actuator drive(s) into both end positions.
NOTES ON INITIALIZING POWER WINDOW REGULATOR
NOTE: initialization is performed on the power window switch of the relevant door.
Initialization comprises:
With normalization, the mechanical end stops of the power window regulator are recorded and stored.
The characteristic curve is learnt immediately after normalization.
When the characteristic curve is learnt, the mechanical closing forces of the power window are recorded and stored for correct operation of the anti-trapping mechanism.
Initialization, i.e. normalization and learning of characteristic curve, is performed in a continuous operation.
NOTE: An initialization must be performed:
WARNING: There is no anti-trapping protection during initialization.
Necessary preliminary tasks
Operating procedure for initialization (manual):
Erasure of initialization
NOTE: Deletion of initialization was successful if one-touch control function and anti-trapping protection have been rendered inoperative.
Performing initialization
NOTE: Re-initialization was successful if one-touch control function and anti-trapping protection function flawlessly.
Alternatively, initialization of the power window regulation can also be carried out via the Service function in ISTA.
Selection via:
REMOVING AND INSTALLING OR REPLACING FLAT MOTOR FOR FRONT LEFT OR RIGHT POWER WINDOW UNIT
Necessary preliminary tasks
NOTE: Position power window unit so that screws of flat motor are freely accessible
Release screws (1) and detach flat motor (2) from power window unit.
Installation: Retaining pins (3) must not be released!
Fig. 59: Identifying Power Window Unit Flat Motor With Mounting Screws And
Pins
IMPORTANT: To ensure tension-free installation of flat motor, observe the specified screwing sequence without fail.
Tighten first screw (1), then screw (2) and finally screw (3).
Tightening torque 67 62 1AZ.
Fig. 60: Identifying Power Window Unit Flat Motor With Mounting Screws
After installation
An initialization must be carried out in order to activate anti-trapping protection.
Read and comply with NOTES on initializing power windows.
REMOVING AND INSTALLING/REPLACING FLAT MOTOR FOR REAR LEFT OR RIGHT POWER WINDOW UNIT
Necessary preliminary tasks
Release screws (1) and detach flat motor (2) from power window unit.
Installation: Retaining pins (3) must not be released!
Fig. 61: Identifying Power Window Unit Flat Motor With Mounting Screws And
Pins
IMPORTANT: To ensure tension-free installation of flat motor, observe the specified screwing sequence.
Tighten first screw (1), then screw (2) and finally screw (3).
Tightening torque 67 62 1AZ.
Fig. 62: Identifying Power Window Unit Flat Motor With Mounting Screws
After installation
An initialization must be carried out in order to activate anti-trapping protection.
Read and comply with NOTES on initializing power windows.
DRIVE, WIPER/HEADLIGHT WASHER SYSTEM
REPLACING WIPER MOTOR
NOTE: Wiper motor can only be replaced in conjunction with wiper console.
Procedure is described in the document "REMOVING AND INSTALLING COMPLETE WIPER CONSOLE ".