REPLACING OIL ACCUMULATOR (GA8HP45Z)

  • Do not let skin come in contact with transmission oil and do not inhale fuel vapors.
  • Wear protective gloves.
  • Ensure adequate ventilation.

IMPORTANT: Applies to vehicles from 08/2011

Remove transmission oil sump only after it has cooled down.

After completion of repair work, check TRANSMISSION OIL LEVEL.

Use only the approved TRANSMISSION OIL.

To set the correct level, it is mandatory that the service function "Transmission control unit: oil adjustment" is performed using the diagnosis system.

Failure to comply with this requirement will result in serious damage to the automatic transmission!

Installation note: The transmission oil sump must be renewed every time it is removed.

Necessary preliminary tasks:

  • Remove transmission oil sump.
  • Remove retaining plates.

Recycling:

Catch and dispose of escaping transmission oil.

Observe country-specific waste disposal regulations.

Release screws (1) (M6x20).

Release screw (2) (M6x59).

Tightening torque 24 30 5AZ.

Carefully unlock cable connector (3) with screwdriver.

Carefully pull out oil accumulator.

IMPORTANT: Mounting bolts of oil accumulator must be replaced after removal.

Hydr/El Control Components/Elements
Fig. 47: Identifying Connector And Screws

REPLACING OIL RESERVOIR (GA8HP70Z)

  • Do not let skin come in contact with transmission oil and do not inhale fuel vapors.
  • Wear protective gloves.
  • Ensure adequate ventilation.

IMPORTANT: Applies to vehicles from 08/2011

After completion of repair work, check TRANSMISSION OIL LEVEL.

Use only the approved TRANSMISSION OIL.

Failure to comply with this requirement will result in serious damage to the automatic transmission!

Necessary preliminary tasks:

  • Remove transmission oil sump.

Release screws (1) (M6x20).

Release screw (2) (M6x59).

Tightening torque 24 30 5AZ.

Carefully unlock cable connector (3) with screwdriver.

Carefully pull out oil accumulator.

IMPORTANT: Mounting bolts of oil accumulator must be replaced after removal.

Hydr/El Control Components/Elements
Fig. 48: Identifying Connector And Screws

    READ NEXT:

     Oil Pump

    REPLACING O-RING ON OIL PUMP (GA6HP19/GA6HP26Z Notes IMPORTANT: After completion of work, check TRANSMISSION OIL LEVEL. Use only approved TRANSMISSION OIL. Failure to comply with this instruction wi

     Controller

    MANUAL EMERGENCY RELEASE OF TRANSMISSION LOCK Manual emergency release of transmission lock from inside vehicle is not possible with GA6HP/GA8HP gearboxes from 03/2010 From production date 04/2010

     Shift Valves, Parking Lock

    SEE MORE:

     Carrying Over Hole Pattern

    When replacing a body component, it is necessary to carry over the hole pattern from the existing body to the new component. The following pictures are a schematic representation of carrying over the hole pattern on the example of the front wheel arch. Necessary preliminary tasks Adjust new part

     Mechanical/Hydraulic Components

    REMOVING AND INSTALLING/REPLACING DSC HYDRAULIC UNIT Necessary preliminary work Read and comply with GENERAL INFORMATION. Remove front left rear WHEEL ARCH PANEL Remove left UNDERBODY PANELLING After completing work: BLEED BRAKE SYSTEM IMPORTANT: Do not mix up brake lines. If necessary, mar

    © 2019-2024 Copyright www.bmw7g11.com