BMW 7 Series: Overview Of Heater - A/C System Components
Fig. 167: Overview Of Heater And A/C System Components
- Condenser for air conditioner
- Drier insert for air conditioner
- Independent heater and attachment parts
- Water valve
- Heater - A/C system and attachment parts
- Fan and attachment parts
- Compressor
SAFETY INSTRUCTIONS FOR HANDLING REFRIGERANT OIL
WARNING: Risk of injury!
Refrigerant circuit is under high pressure! Work on the refrigerant circuit
may only be carried out by experts !
Draw off refrigerant without fail BEFORE all repair work on the refrigerant
circuit.
The refrigerant circuit is depressurized AFTER drawing off!
Protective measures/rules of conduct
- Wear safety goggles
- Wear oil-resistant protective gloves
- Do not smoke!
- Observe country-specific safety regulations.
First aid measures
- If swallowed: Do NOT induce vomiting, unless expressly instructed to do
so by medical personnel. Do
not administer anything to an unconscious person through their mouth.
Consult a doctor immediately if
larger quantities of this substance are swallowed. Loosen tight-fitting
items of clothing (e.g. collar, tie,
belt or similar).
- Eye contact: Remove contact lenses if worn. In the event of eye contact,
rinse eyes for at least 15
minutes with plenty of water. It is essential to use WARM WATER. Consult a
doctor.
- Skin contact: In the event of skin contact, rinse immediately with
plenty of water. Remove contaminated
clothes and shoes. Wash affected clothes before wearing again. Clean shoes
thoroughly before reusing.
Call for a doctor.
- After inhalation: If inhaled, take the person affected outside into
fresh air immediately and keep them
under supervision. Call for a doctor. If breathing difficulties are
experienced, administer additional
oxygen. If the person affected stops breathing, administer the kiss of life.
IMPORTANT: Refrigerant is hygroscopic and must therefore be stored in
suitable containers
that are sealed airtight!
Refrigerant oil is non-combustible and non-explosive at normal temperatures.
Nevertheless, the following points must be observed:
- Do not store in the vicinity of flames, heat sources or strongly
oxidizing
materials
- Suitable extinguishants are carbon dioxide (CO2 ) dry extinguishant
and
foam
Recycling
Catch and dispose of emerging refrigerant oil.
Observe country-specific waste disposal regulations.
Absorb escaping refrigerant oil with fluid-binding material.
Notify the relevant authorities if larger amounts of refrigerant oil are
discharged into aboveground water
supplies, drainage systems or subsoil.
SAFETY INSTRUCTIONS FOR HANDLING TETRAFLUORETHANE REFRIGERANT
R134A
WARNING: Risk of injury!
Refrigerant circuit is under high pressure! Work on the refrigerant circuit
may only be carried out by experts!
Draw off refrigerant without fail BEFORE all repair work on the refrigerant
circuit.
The refrigerant circuit is depressurized AFTER drawing off.
- The pressure gauge on the A/C service unit must be checked for the
actual pressure drop prior to repair work.
It is absolutely essential to read and observe the relevant operating
instructions for the A/C service unit used!
Protective measures/rules of conduct
- Wear safety goggles
- Wear oil-resistant protective gloves
- Do not smoke!
- Observe country-specific safety regulations.
First aid measures
- Eye contact: In the event of contact with the eyes, rinse immediately
with plenty of running water and
consult an ophthalmologist.
- Skin contact: In the event of contact with skin, remove affected
clothing immediately and rinse with
plenty of water.
- After inhalation: If refrigerant vapors are inhaled in greater
concentrations, remove the person affected
to an area of fresh air and keep them under supervision. Call for a doctor.
If breathing problems are
experienced, breathe additional oxygen. If the person affected is breathing
with difficulty or has stopped
breathing, incline the person's head at the neck and administer the kiss of
life.
READ NEXT:
WARNING: When handling cleaning agent, observe following
protective measures:
Wear protective rubber gloves and protective goggles.
If cleaning agent comes into contact with eyes or skin, wash immed
WARNING:
Avoid contact with refrigerant and refrigerant fluid
Follow safety information for handling R134A refrigerant.
Follow safety information for HANDLING REFRIGERANT FLUID
IMPORTANT:
Alway
SEE MORE:
NOTE: See procedure for POWER STEERING PUMP FOR POWER STEERING GEAR
WITH ACTIVE FRONT STEERING (N63) or POWER STEERING PUMP FOR
HYDRAULIC STEERING GEAR WITH DYNAMIC DRIVE (N63).
REMOVING AND INSTALLING/RENEWING DYNAMIC DRIVE EXPANSION HOSE
PART 2 (IN FRONT WHEEL ARCH)
Notes
WARNING: DANGER OF POISON
The following instructions describe the permanent repair gluing of clips
which were originally secured with T-pins.
The repair gluing at the same time protects the area of the torn-off T-pin
permanently against corrosion.
1.0 Information on dangers/hazards
Read and comply with the manufacturer'