Necessary preliminary work
Unlock plug connection (1) on AUC sensor and disconnect.
Fig. 46: Identifying Plug Connection On AUC Sensor
Release screws (1) on blower housing cover (2).
Lift out blower housing cover.
Fig. 47: Identifying Blower Housing Cover Screws
Release screws (1).
Remove actuator drive (2).
Unlock plug connection (3) and disconnect.
Fig. 48: Identifying Actuator Drive, Plug Connection And Screws
Replacement
Servomotors must be re-addressed in the event of replacement! Addressing can only be carried out with the BMW diagnosis system.
Service functions:
REPLACING ACTUATOR DRIVE FOR LEFT BLENDING FLAP
Necessary preliminary tasks
Position of actuator drive:
OVERVIEW OF ACTUATOR DRIVES ON HEATER/AIR CONDITIONER
Release screws (1) and remove grounding cable.
Installation: Replace screws (1).
Take off holder (2).
Fig. 49: Identifying Holder And Screws
Unclip connector piece (1) and slide downwards.
Installation: Latching of connector piece (1) must be felt.
Fig. 50: Unclipping Connector Piece
Release screws (1).
Feed out left footwell air outlet duct (2).
Fig. 51: Identifying Left Footwell Air Outlet Duct And Screws
Unclip deflection arm (1) from deflector (5).
Release screws (4).
Remove actuator drive (2) and unlock and disconnect plug connection (3).
Fig. 52: Identifying Actuator Drive, Plug Connection, Deflection Arm And
Screws
Replacement
Servomotors must be re-addressed in the event of replacement! Addressing can only be carried out with the BMW diagnosis system.
Service functions: