BMW 7 Series: Extension Housing, Bearings, Seal
REPLACING OUTPUT FLANGE SHAFT SEAL (GA6HP26Z/GA6HP32)
Notes
IMPORTANT: After completion of work, check TRANSMISSION OIL LEVEL.
Use only the approved TRANSMISSION FLUID.
Failure to comply with this requirement will result in serious damage to the
automatic transmission!
Necessary preliminary tasks
- Remove underbody protection at front and rear.
- Remove complete EXHAUST SYSTEM.
- Remove TRANSMISSION CROSSMEMBER.
- Remove PROPELLER SHAFT.
Release transmission support block from transmission.
Tightening torque 22 32 1AZ.
Grip output flange (1) with special tool 23 0 020.
Release nut with special tool 24 2 380.
Tightening torque 24 13 1AZ.
Installation:
Replace nut and secure with a mandrel (8 mm) by caulking.
.png)
Fig. 38: Disconnecting Output Flange From Output Shaft Using Special Tool 23
0 020
Detach output flange from output shaft.
Remove spacer.
Attach special tool 24 2 353 to output shaft (1).
.png)
Fig. 39: Connecting Special Tool 24 2 353 To Output Shaft
Screw in special tool 24 2 351 until it is firmly connected with radial shaft
seal.
Pull out radial shaft seal by screwing in special tool 24 2 352.
.png)
Fig. 40: Pulling Out Radial Shaft Seal Using Special Tool 24d 2 352
Oil sealing lip of radial shaft seal (1). Drive in radial shaft seal (1) as
far as it will go using special tool 24 2 370 and adapter ring 24 2 410.
.png)
Fig. 41: Installing Radial Shaft Seal Using Special Tool 24 2 370
READ NEXT:
REPLACING SELECTOR SHAFT SEAL (GA6HP26Z)
Notes
IMPORTANT: After completion of work, check TRANSMISSION OIL LEVEL.
Use only the approved TRANSMISSION FLUID.
Failure to comply with this requirement wi
REPLACING OIL ACCUMULATOR (GA8HP45Z)
Do not let skin come in contact with transmission oil and do not inhale
fuel vapors.
Wear protective gloves.
Ensure adequate ventilation.
IMPORTANT: Applies
REPLACING O-RING ON OIL PUMP (GA6HP19/GA6HP26Z
Notes
IMPORTANT: After completion of work, check TRANSMISSION OIL LEVEL.
Use only approved TRANSMISSION OIL.
Failure to comply with this instruction wi
SEE MORE:
General information
Devices connected to the OBD socket trigger
the alarm system when the vehicle is locked. Remove
any devices connected at the OBD socket
before locking the vehicle.
Safety information
NOTICE
The socket for Onboard Diagnosis is an intricate
component intended to be used in conjunct
ADJUSTING PARKING BRAKE
The parking brake test must be carried out on the dynamic brake analyzer as
follows.
Release position:
Wheel circumferential force right/left < or = 300 N.
Press parking brake button:
Car must be pulled uniformly out of brake roller or drive of brake
roller is dea